• FACP & SPRINKLER FIRE PUMP CONTROL ROOM SIGN- REFLECTIVE !!! (ALUMINUM SIGNS 10X12)

    $9.99
    Free Shipping!

    FACP AND SPRINKLER FIRE PUMP CONTROL ROOM SIGN (REFLECTIVE ALUMINUM SIGNS 10 X 12)


    Size 10 inch x 12 inch

    Sign has mounting holes in each corner.

    Sign Thickness 0.02''

    Sign letters color: WHITE

    Sign background color: RED

    Sign material: Aluminium

    Sign Type: Wall Mounted

    Reflective Sign: Yes

    0.02'' rustproof aluminum

    Standard Engineer Grade reflective

    Rounded corners for easy handling and a professional appearance

    Sign has pre-punched holes to insure a hassle-free installation

    HPD Required sign: NO (See Law and regulations)

    DOB NYC Required sign: NO (See Law and regulations)

    Fire Department required sign: YES (See Law and regulations)

    REQUIRED SIGNS for RESTAURANTS & BARS - N/A (See Law and regulations)

    DOT Required Sign: NO (See Law and regulations)

    DSNY Required Sign: NO (See Law and regulations)

    SKU: HMC NYC MDL NYC 10-12-8301061


    Sign Group: Fire Alarm Control Signs, Fire Department Signs, Sprinkler Control Signs, Fire Pump Room Signs, Fire Control Signs, Sprinkler Room Signs, Fire Alarm Control Panel Signs, Reflective Signs, Red Background Signs, FACP Signs, Fire Pump Signs, Sprinkler Control Room Signs, FACP Control Room Signs


    This is a reflective aluminum “FACP” SIGN with holes for installation.In NYC use/post sign to label control panel & inform owner/tenant/officers/Fire Crew in facilities with aluminum reflective signs/Fire Alarm reflective aluminum signs/F.A.C.P signs


    Our FACP reflective signage comes with four pre-drill holes, which allow you to either use screws and install aluminum sign on walls behind relevant equipment or use Jack Chain/Sturdy Wire and install sign on the equipment it refers to, in which case you can simply hang it where it belongs.

     

    Install a FACP reflective aluminum sign to stay compliant with the relevant laws, regulations and recommendations in force in NYC. Maintain the safety levels required by different federal and municipal agencies and institutions that observe and enforce the law.


    This is a sturdy FACP reflective aluminum sign with RED background, WHITE letters and 4 holes for heavy duty installation. It is a size 10X12 aluminum reflective sign. It is 0.02 inches thick. It is a sign made of sturdy aluminum.

     

    Fire Sprinkler Signs- The signs are designed to identify different controls and pipes for fire sprinkler systems in your facility. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected. Many states require owners to install clear signs identifying the different types of fire sprinklers used.

    There are various types of fire systems. 4 of them are described below:

    Dry Pipe Sprinkler system-Dry pipe sprinklers are similar to pre-action systems as they use pressurized air in the pipe which exits before water escapes. This causes a minute delay in water discharge but is ideal for buildings with low temperatures so the pipes do not freeze. These fire sprinkler systems have a fast opening tool to get rid of the air and speed up the flow of water. Warehouses located in the north are a good example of what buildings should use dry pipe sprinklers.

    Wet Pipe Sprinkler system-Wet pipe fire sprinklers constantly have water in them. This allows for a quick reaction to a fire and is the most common type of sprinkler installed in buildings. A type of building that uses the wet pipe system is a high-rise or office building with a few floors. This fire sprinkler system is cost efficient and low maintenance.

    Pre-action fire sprinkler system-Pre-action fire sprinkler systems are filled with air and water is allowed to pass through when the smoke alarm or detector goes off. This type of system requires two triggers to start water flow. It helps greatly that the pre-action fire sprinkler can be set to prevent water from spouting in case of a false alarm or a mechanical failure. The pre-action system is good for use in places where the sprinklers are only necessary when there is an actual fire so other items in the building do not get water damage from an accidental sprinkling. Such buildings include libraries and data centers. These places contain items of high value like electronics and goods damageable by water such as books

    Deluge Fire Sprinkler -These types of fire sprinkler systems also need a smoke or heat detector like the pre-action system. A deluge system has open nozzles that can be used when a hazard is present. When flammable liquids are spread across a floor, deluge fire sprinklers are good to have. In that case, buildings such as industrial parks and buildings with many tanks have deluge fire sprinkler systems installed.


    The “Fire alarm control panel” sign, also know as “FACP” sign, is designed to inform 1st respondents from the fire department of the location of the Fire alarm control panel. A fire alarm control panel (FACP) can also be named fire alarm control unit (FACU), or simply fire alarm panel.


    The FACP  is the controlling component of the fire alarm system. The panel receives information from devices designed to detect and report fires, monitors their operational integrity and provides for automatic control of equipment, and transmission of information necessary to prepare the facility for fire based on a predetermined sequence. The panel may also supply electrical energy to operate any associated initiating device, notification appliance, control, transmitter, or relay. There are four basic types of panels: coded panels, conventional panels, addressable panels, and multiplex systems

     

    Frequently asked questions:

    How does fire alarm control panel work? Conventional panels represent a building as a series of regions known as detection zones. When a smoke detector or pull switch in a zone activates, the electrical current to the fire alarm panel changes, and the control panel indicates that a device somewhere in that zone has been activated.

    What is the difference between an annunciator panel and a fire alarm control panel? If the fire alarm panel is the heart of the system, then the annunciator is the interface that actually shows you what's going on, and where. Fire alarm annunciators are used to pinpoint the trouble spots, and help the staff monitor the entire building

     

    What information will the fire alarm panel be used to display? In an alarm condition, the fire alarm panel indicates where the alarm originated. The alarm panel can be reset once the device which initiated the alarm is reset, such as returning the handle of a manual pull station to its normal position

     

    What are the components of a fire alarm system? Most fire alarm systems are made up of the following components:

    ü  Fire Alarm Control Panel (FACP)

    ü  Primary and Backup Power Supply.

    ü  Alarm Initiating Device.

    ü  Alarm Notification Device.

    ü  Remote Control and Display Panels.

    ü  Building Safety Interface



    Shipping and Handling Cost:

    Our Shipping is fixed whether you buy 1 item or 20 items (We ship within USA only) - do not miss this opportunity to buy all signs needed at no additional shipping cost.

     

    Sales Tax:

    We are required to collect sales tax on any product sold on this site and shipped to an address in New York. The sales tax is 8.875 percent.

     

    Notice:

    The requirements for sign content are determined by intended use and by applicable regulation. The BUYER is responsible for determining the appropriate content for a sign or package of signs. HPDSigns.com makes no warranty or representation of suitability of a sign for any specific application. IT IS THE CUSTOMER'S RESPONSIBILITY TO ENSURE THAT THE SIGNS THE CUSTOMER ORDERS ARE IN COMPLIANCE WITH ALL STATE, FEDERAL, LOCAL, AND MUNICIPAL LAWS. Please review terms and conditions prior to purchase. 

    We provide both signs required by city and state regulation and Fire Alarm Control Signs , Fire Department Signs , Fire Alarm Control Panel Signs , Reflective Signs , Red Background Signs and FACP Signs


    For more information about what is required, see the laws that are referenced and the rules applicable to your city and state. This page is for informational purposes only and is not intended as legal advice, professional advice or a statement of law. You may wish to consult with an attorney.


    Find us on:

     

    At HPDsigns we specialize with all NYC Department of Building signage (DOB), NYC Housing Preservation and Development signage (HPD) and NYC Department of Transportation signage (DOT). Our objective is to provide property managers, construction site operators and building owners with signs required by NYC agencies and NYC Fire Department, aluminum signs, warnings and notices for quick and heavy duty installation, required building  signs, aluminum signs to install in buildings with proper HPD designation, as well as Fire Alarm Control Signs, Fire Department Signs, Sprinkler Control Signs, Fire Pump Room Signs, Fire Control Signs, Sprinkler Room Signs, Fire Alarm Control Panel Signs, Reflective Signs, Firepump signs, Red Background Signs, F.A.C.P. Signs, Fire Pump Signs, Sprinkler Control Room Signs, F.A.C.P. Control Room Signs, and signs that one can post/use to label control panel & inform owner/tenant/officers/Fire Crew in facilities with aluminum reflective signs/Fire Alarm reflective aluminum signs/F.A.C.P signs


    This is an aluminum “FACP & SPRINKLER FIRE PUMP CONTROL ROOM” SIGN with holes for heavy duty installation. In NYC use/ post sign to inform tenants/owners/guests/officers/Fire Department Crew of designated fire pump control room in facility with proper HPD designation and aluminum signs




    HPD  signs is a McAfee Secure Site!


    We are proud to announce that HPD  signs is a certified McAfee Secure Site. Every day it passes daily extensive security tests. HPD  signs values the protection of consumers. HPD  signs is Not a Compromised Site**. HPD  signs does not employ intended viruses, spyware, and other online threats. HPD  signs is Not a Phishing Site and is Not an Attack Site* with Malware or Malicious Links. Valid SSL Certificate tests. HPD  signs is a certified McAfee Secure website. Every day HPD  signs passes intensive, Daily security scans, which only allow for the use of The McAfee SECURE™ Trustmark on HPD  signs. Every day HPD  signs passes intensive security tests regarding possible personal information access, links to dangerous sites, phishing, and other online dangers. Every day the appearance of The McAfee SECURE™ Trustmark at HPD  signs certifies that HPD  signs passes intensive daily security tests.

     


    *Hackers create attack sites to intentionally host and distribute malicious software.


    **Compromised sites are legitimate sites that are hacked to include content from attack sites.


    HPD  signs is a McAfee Secure Site!


    HPD  signs passes daily security tests!